Water Flow Meter 4 20ma Output
Magnetic Inductive Flow Meter for Sewage Water
Measurement for solid-liquid two-phase liquid
Features
• High-precision measurement/With RS485 or RS232 digital communication signal output
• Electrode material: 1Cr18Ni9Ti,0Cr18Ni12Mo2Ti,Hb,Hc,Ti,Ta,Pt,Ni
• Measurement temperature range: 20℃~150℃
• Pressure grade: 4.0MPa(DN10-150)、1.6MPa(DN10-600)、1.0MPa(DN10-1200)、0.6MPa(DN1000-2000), other preesure customized by customer requirement
• Optional configuration: thermocouple, pressure transmitter and flow totalizer
• Type: electromagnetic flowmeter
• Maximum velocity: 15m/s
• Min. order: 1 piece
• Customization
Promise
Introduction
Reviews
Water Flow Meter 4 20ma Output Overview
The Water Flow Meter 4 20ma Output is a kind of flow meter for sewage water, belonging to the magnetic inductive flow meter. The electromagnetic flowmeter has no moving parts and no flow blocking parts, which will not cause pressure loss, and will not cause problems such as wear and blockage. The flow meter for sewage water is a volume flow measuring instrument, which is not affected by the temperature, viscosity, density, and conductivity (within a certain range) of the measured medium during the measurement process. The electromagnetic flowmeter has a wide range, up to 1:100. In addition, the electromagnetic flowmeter is only proportional to the average flow velocity of the measured medium, and has nothing to do with the axisymmetric flow state (laminar flow or turbulent flow). The electromagnetic flowmeter has no mechanical inertia, sensitive response, can measure instantaneous pulsating flow, and has good linearity, so the measurement signal can be directly converted into a standard signal output by a converter. The LD-T type can indicate on the spot, and the LD type can transmit over a long distance.
Electromagnetic flowmeters are divided into display methods: separate electromagnetic flowmeters and integrated electromagnetic flowmeters. Series nominal diameter DN10 ~ DN2000, such as DN50 flow meter.
A split type electromagnetic flowmeter is an inductive instrument that measures the volume flow of a conductive medium in the pipe according to Faraday's law of electromagnetic induction. It adopts single-chip embedded technology to realize digital excitation. At the same time, the CAN field bus is used on the electromagnetic flowmeter, which is the first in China. The technology has reached the domestic leading level. Split type electromagnetic flowmeter can output 4~20mA current signal for recording, adjustment, and control while satisfying on-site display. It has been widely used in the chemical industry, environmental protection, metallurgy, medicine, papermaking, water supply and drainage, and other industrial technologies and management department. In addition to measuring the flow of general conductive liquids, the split electromagnetic flowmeter can also measure the volume flow of liquid-solid two-phase flow, high-viscosity liquid flow, salt, strong acid, and strong alkali liquid.
The integrated electromagnetic flowmeter is formulated according to Faraday's law of electromagnetic induction and is used to measure the volume flow of conductive fluids. Due to its unique characteristics, it has been widely used in the measurement of various conductive liquids in industry. It is mainly used in the chemical industry, papermaking, food, textile, metallurgy, environmental protection, water supply and drainage, and other industries. It can realize system control by matching with the computer.
Water Flow Meter 4 20ma Output Features
★ Not affected by changes in fluid density, viscosity, temperature, pressure, and electrical rate, the linear measurement principle can achieve high-precision measurement;
★ There are no obstructive flow parts in the measuring pipe, the pressure loss is small, and the requirements for straight pipe sections are low;
★ Nominal diameter DN10-DN2000 covers a wide range, and there are many options for lining and electrodes, which can meet the requirements of measuring various conductive fluids;
★ The converter adopts programmable frequency low-frequency rectangular wave excitation, which improves the stability of flow measurement and reduces power loss;
★ The converter adopts a 16-bit embedded microprocessor, full digital processing, fast operation speed, strong anti-interference ability, reliable measurement, and high accuracy, and the flow measurement range can reach 1500:1;
★ High-definition backlit LCD display, full Chinese character menu operation, easy to use, easy to operate, easy to learn and understand
★ With RS485 or RS232 digital communication signal output
★ It has the function of conductivity measurement, which can judge whether the sensor is empty, and has the function of self-test and self-diagnosis.
★ High circuit reliability with SMD components and surface mount (SMT) technology
★ It can be used in corresponding explosion-proof occasions
Water Flow Meter 4 20ma Output Technical parameter
Magnetic Inductive Flow Meter Technical Parameter | |
Applicable medium | Acid, alkali, salt and pulp, mud, waste water, sea water and solid-liquid two-phase liquid |
Measure medium temperature | 25℃~+150℃(rubber lining 65℃) |
Nominal diameter | DN10-2000 |
Electrode material | 1Cr18Ni9Ti, 0Cr18Ni12Mo2Ti, Hb,Hc,Ti,Ta,Pt,Ni |
Lining material | PTFE (polytetrafluoroethylene), neoprene, polyurethane |
Measurement error | ±0.2%/±0.5%±1.0% flow(according to caliber) |
Media conductivity | >5uS/cm(water>20us/cm) |
Measure range | 0.3~12m/s(Flow unit can be selected) |
Connection flange | GB9115 |
Grounding ring material | Stainless Steel |
Pressure grade | 4.0MPA(DN10-150), 1.6MPA(DN200-600) 1.0MPA(DN700-1200), 0.6MPA(DN1400-2000)(other pressures optional) |
Sensor model | SWP |
Protection | IP65(flameproof and intrinsically safe can be customized) |
Converter model | HX-WP-DM01BHX-WP-DMO1C |
Output signal | 0~10mA or 4~20mA output, frequency/pulse output, passive contact output |
Communication | RS485、RS232 |
Display | Flow rate, unit, flow rate, percentage, empty tube ratio, forward and reverse cumulative amount, forward and reverse cumulative difference, alarm display |
Language | Chinese, English |
Supply power | 220VAC、24VDC |
Water Flow Meter 4 20ma Output Working Principle
The working principle of the electromagnetic flowmeter is based on Faraday's law of electromagnetic induction. When a conductor moves in a magnetic field, an induced electromotive force will be generated at both ends of the conductor perpendicular to the direction of the magnetic field and the direction of motion. The magnitude of the electromotive force is proportional to the speed of the conductor and the magnetic induction of the magnetic field.
How to choose the electromagnetic flowmeter correctly?
What kind of electromagnetic flowmeter to choose should be determined according to the physical and chemical properties of the measured fluid medium. From the working principle of the electromagnetic flowmeter, it can be seen that the fluid that can be used to measure the flow of the electromagnetic flowmeter must be conductive. Strictly speaking, except for high-temperature fluids, any fluid with a conductivity greater than 20us/cm can use the corresponding electromagnetic flow rate. The flow meter is used to measure the flow rate, because the non-conductive gas, steam, oil, acetone, and other substances cannot use the electromagnetic flow meter to measure the flow rate.
Company Profile
CN BOILER ENGINEERING SOLUTION LLC is a comprehensive service provider of thermal energy systems in China, devoted to providing customers with one-step thermal energy system solutions by safe, save energy, environmentally, intelligent, and reliable. Main products include industrial boilers(hot water boilers, steam boilers, thermal oil boilers, waste heat boilers, and CFB boilers), steam generators(electric steam generators, electric hot water generators), intelligent control system by PLC control, PLC+PC control or DCS control, remote instrument and valves, and so on. The control system includes industrial boiler control system(oil fired boilers, gas fired boilers, biomass fired boilers, coal fired boilers, electric boilers, waster heat boilers, CFB boilers), PLC deaerator control system, condensate recovery system, reactor control system, heating exchanger control system, hot air boiler control system etc. The remote instrument and valves include temperature sensors, pressure transmitters, pressure sensors, pressure controllers, liquid level meters, flowmeters, electric control valves, Zirconia, TDS sewage, and so on.
Share your thoughts
Showing
6
of
0
reviews
Most recent
Top Reviews
Read more
Your rating
Your review *
Name *
Enter your Name
Email *
Enter your Email
Upload Image
Notice: Ensure your image is no larger than 200KB before uploading.
Submit
Contact Us Now
Enter your inquiry details, We will reply you in 24 hours.
Name can't be empty
E-mail can't be empty
Company can't be empty
Phone can't be empty
Phone
Products can't be empty
Products you want
Message can't be empty
Verification code error
Clear
People who viewed this item also viewed