Boilers are also widely used in hospitals. Most of the boilers used in hospitals are steam boilers, which can provide sufficient steam for disinfection, laundry, and cooking, heating, purification of air conditioning, bathing, and other links in the hospital. The steam quality of the steam boiler will directly affect the operation of the entire system of the hospital. Once the steam boiler in the hospital fails, it will not only affect the normal operation of the hospital but also pose a major threat to the lives of patients and employees.
It was clear that the hospital needed a boiler that operated reliably and efficiently to meet its enormous steam needs. But a good boiler system is not only to provide sufficient steam, but also to protect the environment and reduce operating costs. The demand for steam will be different during the day and night, so the intelligent boiler control system appears Most importantly, we can run the boiler on demand.
Hospital boilers adopt boiler-shell type corrugated furnace structure, smoke three-pass with a wetback smoke-transfer chamber, spirally corrugated tube tech.The complete set product of boiler consists of burners,boilers, control systems and accessories.This series of products are designed to be safe, reliable, efficient, energy-saving and environmental protection. It also features convenient maintenance, long service life, automatic intelligent control, etc.
Hospital Boilers System Composition
Hospital boiler was clear that the hospital needed a boiler that operated reliably and efficiently to meet its enormous steam needs. But a good boiler system is not only to provide sufficient steam, but also to protect the environment and reduce operating costs. The demand for steam will be different during the day and night, so the intelligent boiler control system appears Most importantly, we can run the boiler on demand.
· Hospital Boilers Combustion system
The combustion system supplies fuel to the hospital boilers for heat generation.
Gas/Oil fired hospital boilers' combustion system equips with burner and fuel device according to the fuel properties, steam capacity and pressure of the boiler.
Burner brand: Baltur, Riello, Weishaupt, Hofamat, Honeywell, Ecoflam, Cavallo and so on.
· Hospital Boilers Steam water system
The steam water system consists of feedwater part and steam part.
Feedwater part: Feedwater refers to the water that is provided to the boiler for steam conversion. The feedwater channels water into the boiler and automatically controls it to satisfy steam requirements.
Steam part: the steam is the part of the boiler responsible for collecting and regulating the steam generated by the boiler. Valves and pressure gauge controls are used to monitor and regulate steam pressure.
The steam and water system should be composed of boiler main body, rear heating surface(such as economizer,condenser and so on which are equipped according to actual situation of user), water treatment device, feed water pump, steam header, deaerator and so on.
· Hospital Boilers Control system
Hospital boilers control system is a collection of boiler electrical control components, a center for collecting and processing boiler operating signals, and an operation platform for sending execution instructions to each execution unit of the boiler.
The control system circuit of the hospital boilers is relatively complicated, and the core role is the PLC or DCS control. We can program the PLC logic according to the specific requirements of the customer. The steam boiler control system circuit is mainly composed of logic editing PLC, terminals, modules, control panels, frequency converters, switches, isolation barrier, etc. The circuit drawings are mainly composed of primary circuit diagrams, secondary circuit diagrams, terminal wiring diagrams, PLC point diagrams, etc. Now one of the PLC point diagrams is shown as follows:
All of these control system circuits will be reflected in control cabinets, and the boiler control system is operated on the control cabinet. We have many different and similar control cabinets. Types of control cabinets for wood pellet steam boiler: wall-mounted control cabinet, podium control cabinet, MCC vertical control cabinet, piano-style control cabinet, positive pressure explosion-proof control cabinets, and three-proof control cabinet. Each control cabinet we leave the factory has a unique number, and it has the function of mobile phone viewing. You can see the operating status of the boiler in real-time, such as temperature, water level, pressure, alarm record, etc. But the actual operation still needs to be completed by the staff in the boiler room. The control cabinets picture is shown as follows:
Hospital Boilers Technical Parameter
Model
WNS6-1.25-Q.Y
WNS6-1.6-Q.Y
WNS8-1.25-Q.Y
WNS8-1.6-Q.Y
WNS10-1.25-Q.Y
WNS10-1.6-Q.Y
WNS15-1.25-Q.Y
WNS15-1.6-Q.Y
WNS20-1.25-Q.Y
WNS20-1.6-Q.Y
Rated steam capacity(t/h)
6
8
10
15
20
Rated working pressure(Bar)
1.25/1.6
1.25/1.6
1.25/1.6
1.25/1.6
1.25/1.6
Rated steam temperature(℃)
194/204
Feed water temperature ℃
20
Boiler Main Body Heating Area(m²)
181.17
190.77
229.95
346.2
467.6
Condenser Heating area(m²)
78.25
108.5
165.3
216.2
360.3
Thermal Efficiency(%)
>98
Fuel available
natural gas、biogas、coke gas,light oil.methanol.biodiesel etc.
Combustion equipment
burner
Total power(kW)
19.5
29.5
33
90.5
Fuel--Natural gas(m³)
432
576
720
1080
1440
Fuel--light oil(L)
399
532
660
997
1204
Max Transportation Weight( t )
19.5
22.6
25.8
34.7
46
Max boiler shipping size:L×W×H(m)
5.93×2.60×3.02
5.85×2.80×3.10
7.65×2.81×3.10
6.95×3.10×3.60
8.30×3.40×4.02
Note: Parameter is for reference only, if any changes should follow the factory technical data.
Hospital Boilers Boiler Parts
Hospital Boilers auxiliary equipment includes burner, water pump, control cabinet, energy saver, condenser, steam cylinder, boiler water treatment equipment, instrument valves and so on. The parts and functions of the steam boiler are as the attached pdf--Steam Boiler Parts and Function. The steam boiler parts diagram is as follow:
Company Profile
CN BOILER ENGINEERING SOLUTION LLC is a comprehensive service provider of thermal energy systems in China, devoted to providing customers with one-step thermal energy system solutions by safe, save energy, environmentally, intelligent, and reliable. Main products include industrial boilers(hot water boilers, steam boilers, thermal oil boilers, waste heat boilers, and CFB boilers), steam generators(electric steam generators, electric hot water generators), intelligent control system by PLC control, PLC+PC control or DCS control, remote instrument and valves, and so on. The control system includes industrial boiler control system(oil fired boilers, gas fired boilers, biomass fired boilers, coal fired boilers, electric boilers, waster heat boilers, CFB boilers), PLC deaerator control system, condensate recovery system, reactor control system, heating exchanger control system, hot air boiler control system, etc. The remote instrument and valves include temperature sensors, pressure transmitters, pressure sensors, pressure controllers, liquid level meters, flowmeters, electric control valves, Zirconia, TDS sewage, and so on.
CN Boiler has always adhered to the concept of full electrical integration in the industrial energy industry, that is, integrating strong and weak current systems such as boiler control, boiler room auxiliary machine control, upper monitoring system, and boiler room power distribution system into a complete electrical package, forming a characteristic industrial energy control system (CN Boiler Multi-Boiler Control System, referred to as CN Boiler- MBCS). As the main power source of industrial enterprises, steam boilers are widely used in various fields of industrial processes, such as metallurgy, chemical industry, machinery, papermaking, medicine, the food light industry, and so on. In recent years, the number of applications of gas-fired steam boilers in industrial processes has increased significantly.
We use cookies to make the website work, to provide advanced features, social media and traffic analysis, and we use analytics and third-party advertising cookies. If you choose to click "Deny All", you will retain the default setting of not allowing the use of cookies or other tracking tools other than technical tools.
Room 301, Floor 3, Building 7, No. 16 Jinzhan Street, High and New Technology Development Zone, Zhengzhou City